Current Calibrators

Hand Held Current Calibrators

Product Details:
  • Usage: Industrial

We provide Hand Held Current Calibrators having Programmable (D.C. Current)mode.Being one of the most reliable and efficient companies in this line of work, our company is offering one of the most trusted quality products for various electronic works.

Technical Specifications:

  • Input : 0-25.00 mA D.C. Software Programmable
  • Resolution : 0.01 count
  • Accuracy : ± 1 count ± L.S.B Over Full Range
  • Min. and max. setting : Software Programmable
  • Scale and decimal point, √ : Software Programmable
  • Output(Linear/Toggle) : 0-25.00 mA D. C. Software Programmable
  • Resolution : 0.01 count
  • Accuracy : ± 0.25% ± L.S.B Over Full Range
  • Max. load : 270 (22.00Ma), 100(25.00Ma)
  • Display : 4 digit Red LED display
  • Unit On time with emergency : 1 – 999 Sec. Software Programmable
  • shutdown facility
  • Input power supply : 3.6V/1500mAH D.C. battery
  • Dimension (mm) : 150*100*40 (H*W*D)

 

Conformity with Indian National Standards:

 

Mode : Programmable (D.C. Current)


System operation:


  • To Edit the parameters use (Enter Key)
  • To Set the parameters use Increment, Decrement, Shift Keys
  • To Accept the parameters use (Enter key)
  • D (Small letter is flashing of digit) indicates next setting is allowed


To Set Input/Output Mode:


  • Switch on calibrator with On Key while pressing key


Key Display Function:


  • Key & Release : Edit Edit Mode
  • Key : Mode
  • Key : 0, 1, 2 0 (I/P), 1(O/P), 2(Hi-LO Toggle O/P),
  • Key : Power Off
  • To Set On Time
  • Switch on calibrator with On Key


Key Display Function:


  • Key : Edit Edit Mode
  • Key : Time
  • Key : 060 1 – 999 Sec
  • Key : Power Off
  • To Set mA output (Linear mode)
  • Switch on calibrator with ON key


Key Display Function:


  • Set Edit Mode
  • Key : 00.00 00.00 mA |
  • key : AB.CD In range value | LOOP
  • Key : AB.CD Ready for next setting |
  • key: 90.00
  • Key : Power Off
  • To Set mA output (Toggle mode)
  • Switch on calibrator with On Key

 

 Set Edit mode:


  • Key : Lorn set lo mA o/p
  • Key : Hirn set hi mA o/p | LOOP
  • Key : Lorn set lo mA o/p |
  • Key : Power Off
Looking for Current Calibrators ?
© Unique Technical Services (Unit Of Kalashri Electronics Private Limited)
 